The ansul fm 200 clean agent fire suppression system is approved by factory mutual fm and listed by underwriters laboratories ul for class a b and c fires.
Clean agent fire suppression system specification.
Design supply and install a complete clean agent total flooding fire suppression system using novec 1230 fire protection fluid hereafter referred to as system which meets all the performance criteria described herein.
Ansul technical bulletin replacement components and service genuine ansul replacement components recommended for installation on ansul products rev.
21 1314d automatic sprinkler systems dry pipe new 21 1314w automatic sprinler systems wet pipe systems new 21 2400ca clean agent chemical suppression systems new.
For speed in suppressing fires reducing damages saving on floor space and allowing visibility fike is the clear choice.
02 specifications english f 2003240 pdf view.
Section title 21 0000 general fire suppression requirements.
Our clean agent fire protection system which includes the use of hfc 227ea and fm 200 leaves no residue and doesn t require costly clean up unlike sprinklers and other fire protection systems and it discharges in 10 seconds or less extinguishing a fire quickly and.
21 0800 commissioning of fire suppression systems.
The work described in this specification includes all engineering labor materials equipment and services necessary and required to complete and test the suppression system.
Clean agent fire suppression system revised 4 30 2015 21 22 00 4 fire suppression guide specification b.
Summary of work a.
Ansul sapphire clean agent fire suppression system with autopulse z 10 conventional detection system engineering specifications rev.
Copy and paste the following text into your specification or download the full specification example.
Safe for use in occupied areas at the design concentration the system helps protect critical infrastructure and delivers effective asset protection.
The addressable control panel shall be ul listed and factory mutual global fmg approved for use as a local fire alarm system and or releasing clean agent deluge and pre action sprinkler fire suppression systems.
Fire suppression system data specification sheet general the fm 200 fire suppression system is an engineered system utilizing a fixed nozzle agent distribution network the system is designed and installed in accordance with the national fire protection association nfpa standard 2001 clean agent fire extinguishing systems.
Featuring an excellent safety profile with a 20 year environmental warranty novec 1230 is trusted in data centers engine rooms museums.
Clean agent fire suppression fluid a.
This specification outlines the requirements for a total flood clean agent fire suppression system with automatic detection and control.
Unified facilities guide specifications references are in agreement with umrl dated april 2020 section table of contents division 21 fire suppression section 21 22 00 00 40 clean agent fire extinguishing systems 05 16 part 1 general 1 1 references 1 2 submittals 1 3 quality control 1 3 1 special hazards suppression systems.